Allen-Bradley PLC-5: Replacement & Cross-Reference
The Allen-Bradley PLC-5 (1785-L series) is a discontinued large PLC platform. Rockwell's migration path is ControlLogix (1756), with conversion tools from RSLogix 5 to Studio 5000 and options to keep DH+ and 1771 I/O during a phased cutover. For plants holding PLC-5 lines, Edmundson Industrial sources new-surplus, used-tested, and reconditioned PLC-5 processors, 1771 I/O, and chassis.
Status
| Brand | Allen-Bradley / Rockwell Automation |
| Family | PLC-5 (1785 series) |
| Common catalog numbers | 1785-L11B, L20B, L40B, L60B, L80B · 1785-L40E / L80E (Ethernet) · 1771 I/O |
| Lifecycle | Discontinued / end-of-life: verify current Rockwell status at quote |
| Programming | RSLogix 5 (legacy) |
Cross-Reference
| If you have (obsolete) | Recommended path | Notes |
|---|---|---|
| PLC-5 processor (1785-L…) | ControlLogix 1756-L8 | Convert RSLogix 5 to Studio 5000; plan the I/O strategy and checkout time. |
| PLC-5 on a DH+ network | ControlLogix with DH+ bridge (1756-DHRIO) | Keep DH+ / RIO devices during a phased migration. |
| 1771 I/O | Reuse on migration, or like-for-like surplus | 1771 reuse paths exist; confirm module support when planning. |
| Keep the program: no re-engineering | New-surplus / used-tested PLC-5 (we source) | Keeps the installed program. Match processor memory, comms, and series/revision. |
Cross-references are starting points: confirm processor memory, communications, and program compatibility before substituting. We'll verify on request.
Key Specs
- Large rack-based PLC using 1771 I/O
- Communications: DH+, Remote I/O (RIO), RS-232, and Ethernet on E models
- Battery-backed memory; processor sizes from 1785-L11B to L80B
- Programmed in RSLogix 5; does not convert directly to Studio 5000 without tools
- Confirm processor series/revision and channel configuration on the nameplate
Is the PLC-5 still made?
No. ControlLogix is the successor platform. PLC-5 still runs major process, utility, and heavy-industry systems, so spares, processor, 1771 I/O, memory battery, buy time to migrate on a planned schedule rather than during an outage. We source the originals and quote the ControlLogix path.
FAQ
Is the Allen-Bradley PLC-5 discontinued?
What replaces a PLC-5?
Can I still buy PLC-5 processors and I/O?
Can I reuse my 1771 I/O when migrating?
What do you need to quote PLC-5 parts?
Availability & Quote
Condition disclosed before sale, new-surplus, used-tested, or reconditioned, with photos on request.
or send catalog numbers to sales@edmundsonindustrial.com · (832) 975-8827 · Houston, TX. Response timing is confirmed with the request.
Related Allen-Bradley legacy pages
Want a quick quote for Allen-Bradley PLC-5?
Fill out your contact info here, and we'll get a quote sent to you ASAP!