Ross Hill 0301-0013-00 Fuse, ATQ10
ATQ10 combines a 10 A rating with the ATQ time-delay curve and 500 VAC class; all three remain part of the selection.
Ross Hill 0301-0013-00 identifies the 10 A ATQ10 time-delay midget fuse, cataloged by Mersen as ATQ10. The exact item is rated 500 VAC at 50/60 Hz in a 10 x 38 mm ferrule format. Mersen classifies ATQ as a 500 VAC midget time-delay series for supplemental protection. The family data publishes a 12-second time delay at 200 percent rating and a 10 kA interrupting rating.
Independent supplier. Edmundson Industrial is not appointed, endorsed, or sponsored by Ross Hill, NOV, GE, ABB, Mersen, or any other manufacturer named on this page. Names and part numbers appear for identification only. Availability, condition, price, and lead time are confirmed for each request.
| RHCC part number | 0301-0013-00 |
|---|---|
| Manufacturer catalog number | ATQ10 |
| Common reference | ATQ10 |
| Series | Mersen ATQ midget time-delay |
| Ampere rating | 10 A |
| Rated voltage | 500 VAC, 50/60 Hz |
| Form | Ferrule midget, 10 x 38 mm (1-1/2 x 13/32 in.) |
| Interrupting rating | 10 kA at rated AC voltage |
| Protection role | Supplemental protection; not branch-circuit protection |
Part-number identification
ATQ10 fixes the manufacturer family, 10 A rating, time-delay characteristic, voltage class, and physical format. Match all of those fields with the fuse holder, protected load, and available fault current.
The complete installed label remains the ordering reference. Match the part number, electrical ratings, physical interface, and circuit duty before approving a replacement.
ATQ time delay protects control circuits through inrush
Control transformers, solenoids, and motor-control circuits can draw temporary inrush. The published ATQ delay prevents a permitted short-duration inrush from being treated like a sustained overcurrent. Coordination still depends on the actual load and equipment design.
Supplemental protection is the application boundary
Mersen states that ATQ10 is not for branch-circuit protection. Use it only where the equipment design calls for a supplemental midget fuse. A matching ampere and voltage marking does not authorize a different protection role.
The holder is part of the selection
The 10 x 38 mm (1-1/2 x 13/32 in.) cartridge must be checked with the installed holder. Confirm the holder catalog number, voltage rating, terminal condition, rejection or indication features, required approvals, and the circuit fault duty before returning it to service.
Ten amperes does not identify the time-current curve
A 10 A cartridge can be fast-acting, time-delay, branch-rated, or supplemental. ATQ10 specifically identifies the ATQ time-delay supplemental form. Preserve the complete catalog number so a general 10 A search does not substitute a different protection characteristic.
Also searched as
0301-0013-00 · 0301001300 · ATQ10 · ATQ 10 amp fuse · Mersen ATQ10
What to send with your request
Identify the exact series, time characteristic, voltage, ampere rating, and holder.
- Complete RHCC number and every catalog marking on the fuse
- Photographs of the fuse and holder markings
- Circuit voltage, frequency, and AC or DC designation
- Protected load, expected inrush, and equipment function
- Required approvals, holder number, and available fault-current information
- Quantity required, acceptable condition, and need-by date
A purchase order is not required for an identification review. Send the complete numbers and clear equipment photographs so the quoted item can be checked against the application.
Related
Identification checkpoint
For RHCC 0301-0013-00, confirm manufacturer catalog number: ATQ10; series: Mersen ATQ midget time-delay; ampere rating: 10 A. Use the installed label and complete suffix before treating another item as equivalent.
Why ATQ10 must stay exact
ATQ10 is the 10 A record for RHCC 0301-0013-00. It must not be collapsed into the 3.5 A or 6 A ATQ records simply because all three use the same midget form. Confirm the ATQ10 catalog marking, 500 VAC class, circuit duty, and holder before replacement.
FAQ
What is Ross Hill 0301-0013-00?
What are the electrical ratings of ATQ10?
What size is ATQ10?
Is ATQ10 a branch-circuit fuse?
Can a fuse be selected by ampere rating alone?
Availability & Quote
Want a quick quote for 0301-0013-00?
Fill out your contact info here, and we'll get a quote sent to you ASAP!