EDMUNDSON INDUSTRIALINDUSTRIAL ELECTRICAL SUPPLY
HomeSpecialtiesDrilling Rig Electrical6702ED584-2
Drilling Rig Electrical · SCR bay contactors

Eaton / Cutler-Hammer 6702ED584-2 — DC Contactor

The suffixed variant of the 1800 A DC contactor found in Ross Hill SCR bays — same frame, different coil voltage. That difference is the whole reason this page exists.

Independent sourcing, not an authorized distributor. Eaton, Cutler-Hammer, Ross Hill, NOV, and other manufacturer names and part numbers are used for reference only. Supplied as new-surplus, used-tested, or reconditioned, with condition disclosed before sale.

Manufacturer part number6702ED584-2
ManufacturerEaton / Cutler-Hammer
EI referenceEI-6702ED584-2
TypeDC contactor
Rating on fileSame 1800 A frame as the 6702ED584, listed by distributors with a 115 VDC coil
Base number6702ED584 — 1800 A, 74 VDC coil
Found inRoss Hill / NOV SCR bays
ConditionNew-surplus, used-tested, reconditioned

Also searched as

6702ED584-2 · 6702ED584 2 · 6702ED-584-2 · 6702 ED 584 2 · 6702ED5842 · Cutler-Hammer 6702ED584-2 · Eaton 6702ED584-2 · 1800 amp DC contactor 115 VDC coil · Ross Hill SCR bay contactor · EI-6702ED584-2

What does the -2 suffix change?

The coil voltage. The base 6702ED584 is recorded as 1800 A with a 74 VDC coil. The -2 is recorded as the same 1800 A frame, listed by distributors with a 115 VDC coil.

The frame and the current rating are the parts of the number people read. The coil voltage is the part that decides whether the contactor works in your bay. It is a one-character difference on a nine-character number and it is the single most expensive thing to get wrong on this family.

What happens if you fit the wrong coil voltage?

A contactor with the wrong coil voltage will either fail to pull in or run hot and fail early. Neither failure mode announces itself as a coil problem, which is why it costs people a second contactor before they find it.

Under-driven, the coil does not develop enough force to seat the contacts — you get a contactor that will not pull in, or one that chatters and drops out under load. Over-driven, it seats fine and cooks. Read the whole number off the nameplate, including any suffix, and tell us the coil voltage your bay actually supplies.

The 6702ED family — read the whole number

Recorded variants in and around the Eaton / Cutler-Hammer 6702ED contactor family as they appear in our records. Reference only — confirm against the nameplate before ordering.
NumberWhat is recordedNote
6702ED584-2Same 1800 A frame, listed by distributors with a 115 VDC coil.this page
6702ED584DC contactor, 1800 A, 74 VDC coil. Catalogued by Ross Hill as 0401-0021-00.Different coil voltage
6702ED587-2DC contactor, 3000 A, 74 VDC.Different current rating
6702ED621-2DC contactor, 1000 A, 125 VDC, reversing.Different rating and coil
0100-0389-02Ross Hill 1800/C contactor, 1800 A 74 VDC. A Ross Hill-built part, not an Eaton one.Same headline rating, different manufacturer

Note the trap at the bottom of the table. Two different 1800 A contactors turn up in this equipment from two different manufacturers. Matching ratings do not make them interchangeable — check the manufacturer name on the nameplate, not just the rating.

Is this an Eaton part or a Ross Hill part?

An Eaton / Cutler-Hammer part. Ross Hill specified the 6702ED family into its SCR bays and catalogued the base number under a Ross Hill number, 0401-0021-00, but Ross Hill did not build it.

That has a practical consequence worth knowing: the part has a life independent of the Ross Hill parts chain, and a search against the Eaton number will usually turn up more than a search against the Ross Hill number. If you have only been quoted against a Ross Hill number, try the Eaton number.

Symptoms that point here

Failure signatures our records associate with DC contactors in this family. Diagnostic starting points, not a substitute for a qualified rig electrician.
What you are seeingWhat it usually indicates
Contactor will not pull inCoil, coil voltage, or control circuit — verify the coil rating first
Contactor chatters or drops out under loadCoil supply or worn contacts
Heavy pitting or welding on the tipsContacts at end of life, or an interruption duty problem
Replacement fitted and it runs hotWrong coil voltage variant — check the suffix

Starting from a symptom — a gate firing pulse failure, a misfire, phase loss, one leg dead? The SCR Drive Fault Finder maps what you are seeing to the suspect module and part number.

Nameplate

We verify the full number, including suffix, and the coil voltage against the physical unit before quoting, and send photos of the nameplate on the unit being offered. On this family the nameplate photo is worth more than the purchase record.

What to send us

These are the details that let us identify the right unit instead of guessing at it.

Condition & sourcing

Supplied as new-surplus (unused, from the secondary market), used-tested, or reconditioned, with condition disclosed before sale and photos on request. Availability on legacy Ross Hill and NOV equipment changes constantly — send the number and we will tell you what we can actually find.

Related

FAQ

What is the difference between 6702ED584 and 6702ED584-2?
The coil voltage. The base 6702ED584 is recorded as 1800 A with a 74 VDC coil. The -2 is recorded as the same 1800 A frame, listed by distributors with a 115 VDC coil. Read the whole number including the suffix before ordering.
Will a 6702ED584-2 work in place of a 6702ED584?
Not unless your bay supplies the coil voltage it expects. A contactor with the wrong coil voltage will either fail to pull in or run hot and fail early. Confirm the coil voltage your bay actually supplies, not just the current rating.
Is the 6702ED584-2 an Eaton part or a Ross Hill part?
It is an Eaton / Cutler-Hammer part. Ross Hill specified the 6702ED family into its SCR bays and catalogued the base number under a Ross Hill number, 0401-0021-00, but Ross Hill did not build it.
Can I substitute the Ross Hill 0100-0389-02 for it?
No. The Ross Hill 0100-0389-02 shares the 1800 A headline rating with the base 6702ED584 and is a genuinely different part from a different manufacturer. Matching ratings do not make two contactors interchangeable — check the manufacturer name on the nameplate.
My contactor will not pull in. Is that the coil?
It is the first thing to check. A contactor that will not pull in usually points at the coil, the coil voltage, or the control circuit — verify the coil rating first. If a replacement was fitted recently and it runs hot, check the suffix on what was installed.
Can you supply one?
We source these as new-surplus, used-tested, and reconditioned, with condition disclosed before sale and nameplate photos on request. Send the full number and the coil voltage your bay supplies.

Availability & Quote

Condition always disclosed before sale. Photos on request. Same-day response on most requests.

Request a Quote or send the part number to sales@edmundsonindustrial.com(832) 975-8827Houston, TX.

Send the full number and the coil voltage your bay supplies.

Condition disclosed before sale. Nameplate photos on request.

Request a Quote