Ross Hill 0302-0513-00 Circuit Breaker, THED136150WL
THED136150WL is the complete 150 A THED E150 identity; frame, poles, voltage, trip construction, lugs, and mounting all remain part of the order.
Ross Hill 0302-0513-00 identifies the ABB THED136150WL molded-case circuit breaker. ABB catalogs the exact number in the THED high-break E150 line as a 150 A, three-pole, 600 VAC thermal-magnetic breaker with noninterchangeable trip and copper/aluminum line and load lugs.
Independent supplier. Edmundson Industrial is not appointed, endorsed, or sponsored by Ross Hill, NOV, GE, ABB, Mersen, or any other manufacturer named on this page. Names and part numbers appear for identification only. Availability, condition, price, and lead time are confirmed for each request.
| RHCC part number | 0302-0513-00 |
|---|---|
| Manufacturer reference | THED136150WL |
| Breaker line | ABB THED high-break E150 |
| Ampere rating | 150 A |
| Poles | Three |
| Rated voltage | 600 VAC |
| Trip | Thermal-magnetic, noninterchangeable |
| Cataloged lugs | Copper/aluminum line and load lugs |
| Selection checks | Interrupting rating, mounting, terminals, accessories, and circuit fault duty |
Part-number identification
THED136150WL fixes the THED family and 150 A catalog position. Match the complete nameplate and installed configuration before approving a breaker, especially interrupting markings, lugs, mounting, accessory wiring, and bucket interlocks.
The complete installed label remains the ordering reference. Match the part number, electrical ratings, physical interface, and circuit duty before approving a replacement.
THED identifies the high-break E150 line
THED is not interchangeable shorthand for TEB or TED. ABB separates these families by voltage and performance in the E150 table. Preserve the full THED prefix, the 136 configuration, ampere digits, and WL suffix throughout the request.
Thermal and magnetic protection are built into the trip
The thermal element responds to sustained overcurrent and the magnetic element responds to high-current faults. A replacement comparison must address both functions along with the equipment coordination study; a matching handle rating does not complete that review.
The 150 A entry is the upper rating in this E150 table
ABB lists THED136150WL at the 150 A end of the E150 three-pole table and applies a 75 degrees C temperature note above 100 A. Verify the installed terminal markings, conductor rating, enclosure temperature, and equipment listing before approving the connection.
Inspect lugs, mounting, and accessories
ABB catalogs copper/aluminum line and load lugs with the three-pole breaker. Verify the actual lug markings, conductor material and size, torque requirements, line-load orientation, mounting feet, handle operator, auxiliary devices, and enclosure clearances on the installed unit.
Also searched as
0302-0513-00 · 0302051300 · THED136150WL · THED136150 · THED 150 amp breaker · ABB E150 150 A
What to send with your request
Match the exact THED catalog number and every installed breaker interface.
- Complete RHCC and THED numbers, including WL
- Photographs of the nameplate, handle, lugs, sides, rear, mounting, and bucket
- Circuit voltage, poles, load, and available fault-current information
- Interrupting-rating, listing, and temperature markings
- Conductor material and size, lug markings, accessories, and operating mechanism
- Quantity required, acceptable condition, and need-by date
A purchase order is not required for an identification review. Send the complete numbers and clear equipment photographs so the quoted item can be checked against the application.
Related
Identification checkpoint
For RHCC 0302-0513-00, confirm manufacturer reference: THED136150WL; ampere rating: 150 A; rated voltage: 600 VAC. Use the installed label and complete suffix before treating another item as equivalent.
Distinguish the 150 A breaker
RHCC 0302-0513-00 maps to THED136150WL at 150 A. The neighboring RHCC 0302-0504-00 record is THED136100WL at 100 A. Similar frame language does not erase the trip rating; match the complete THED number, mounting, terminals, accessories, and circuit fault duty.
FAQ
What is Ross Hill 0302-0513-00?
How many poles and what voltage does THED136150WL have?
What trip construction does THED136150WL use?
Are lugs included in the catalog configuration?
Is matching the ampere rating enough?
Availability & Quote
Want a quick quote for 0302-0513-00?
Fill out your contact info here, and we'll get a quote sent to you ASAP!