Ross Hill 0302-1509-00 Motor Circuit Protector, TEC36007WL
Ross Hill 0302-1509-00 identifies TEC36007WL, a 7 A magnetic-only motor circuit protector with documented pickup positions from 18 to 90 A.
Ross Hill 0302-1509-00 identifies TEC36007WL, a 7 A magnetic-only motor circuit protector with documented pickup positions from 18 to 90 A. Use the complete installed identifiers and equipment ratings as the ordering reference. Availability, condition, price, and lead time are confirmed for each request.
Independent supplier. Edmundson Industrial is not appointed, endorsed, or sponsored by any manufacturer named on this page. Ross Hill, NOV, GE, ABB, TE Connectivity, Potter & Brumfield, Mersen, ZF, Cherry, Clarostat, and other names and part numbers appear for identification only. Their use does not imply endorsement or a current manufacturer relationship. Availability, condition, price, and lead time are confirmed for each request.
| RHCC part number | 0302-1509-00 |
|---|---|
| Part description | CB-MAG/TRIP, 7A |
| Manufacturer reference | TEC36007WL |
| System context | MCC |
| Corroborated device context | Three-pole, 600 V, magnetic-only motor circuit protector |
| Instantaneous pickup positions | 18, 30, 42, 54, 65, 78, and 90 A |
| Published conflict | One GE-formatted exact sheet has a 3 A technical-table field |
Magnetic-only protection is not a thermal overload
A motor circuit protector responds to high fault current through its magnetic pickup. Motor overload protection remains a separate coordinated function. Confirm the overload relay and heater selection in the starter rather than expecting the TEC device to perform both jobs.
Also searched as
0302-1509-00 · 0302150900 · TEC36007WL · TEC36007 · 7 amp magnetic motor circuit protector
What to send with your request
Keep continuous current, magnetic pickup, suffix, and overload coordination in separate fields.
- The complete RHCC and TEC number, including WL if present
- Photographs of the label, pickup dial, lugs, frame, mounting, and full bucket
- The selected pickup position and reason for that setting
- Motor nameplate current, voltage, phase, horsepower, and service factor
- Overload relay and heater numbers in the same starter circuit
- Circuit fault-duty information, quantity required, and need-by date
Related
Identification checkpoint
For RHCC 0302-1509-00, confirm manufacturer reference: TEC36007WL; corroborated device context: Three-pole, 600 V, magnetic-only motor circuit protector; instantaneous pickup positions: 18, 30, 42, 54, 65, 78, and 90 A. Use the installed label and complete suffix before treating another item as equivalent.
FAQ
What is Ross Hill 0302-1509-00?
What do the 18 to 90 A values mean?
Does the protector provide motor overload protection?
What should be verified before ordering 0302-1509-00?