EDMUNDSON INDUSTRIALOILFIELD ELECTRICAL SUPPLY
Drilling Rig Electrical · MCC group motor circuit protector

Ross Hill 0302-1500-00 Motor Circuit Protector, GE TEC36030WL

Ross Hill 0302-1500-00 identifies GE TEC36030WL, a 30 A magnetic-only motor circuit protector; keep continuous current separate from magnetic pickup settings.

Use the complete installed identifiers and equipment ratings as the ordering reference. Condition is stated with the offer.

Independent supplier. Edmundson Industrial is not appointed, endorsed, or sponsored by any manufacturer named on this page. Ross Hill, NOV, GE, Bussmann, Ohmite, Hoyt and other manufacturer names and part numbers appear here for identification only. Their use does not imply authorization, endorsement, or any current manufacturer relationship. Condition is stated with the offer.

Identification details for Ross Hill 0302-1500-00
RHCC part number0302-1500-00
Part descriptionCB-MAG/TRIP, 30A
Manufacturer referenceTEC36030WL
GE frame and familyE150 frame, TEC series Mag-Break
Poles and rating3 pole, 30 A, 600 V
TripMagnetic only. No thermal overload element.
Published trip settingsLow 90, high 390
Published interrupting rating10 kA at 480 V, feed-thru, UL listed
Manufacturer status reportedDiscontinued, per seller listings

A TEC is not a THED

Fitting a TEC where a THED belongs removes the overload element from that circuit. Fitting a THED where a TEC belongs adds a thermal element to a circuit already protected by a starter overload, which is likely to nuisance trip on motor starting current. Neither is a substitution we publish.

Magnetic only is deliberate, not a cheaper option

A motor draws several times its running current for the first moments of a start. A thermal element sized to protect the motor in normal running will see that inrush and may trip on it. So on a motor circuit the protection is often split: the breaker handles short circuit with a magnetic trip only, and the starter overload relay handles sustained overload with heaters chosen for the motor.

Review the complete requirement

Send the complete part number, label photos, equipment details, and any proposed replacement already included in your requirement. EI reviews the identification and configuration with your quote request; a similar number or rating does not establish fit.

What to send with your request

Tell us what it works with, because on a motor circuit the breaker is half of a scheme.

  • The ampere rating and any trip setting marked on the existing device
  • The starter and overload relay the breaker works with, if you know them
  • A photograph of the breaker label showing the catalogue number and any suffix
  • Whether you are replacing after a fault or as part of a planned rebuild
  • Quantity required, the condition you can accept, and your need-by date

Send the number and photograph with your parts requirement for EI review and a quote.

Related

Questions we get on this number

What are the trip settings?
Independent listings publish a low position of 90 and a high position of 390 for this reference, with a 10 kA interrupting rating at 480 V. Where to set it for a given motor is an engineering decision and we do not publish a recommendation.
Is it still made?
Seller listings describe the reference as discontinued by the manufacturer. That is their statement, reported here because it is useful to a buyer. It says nothing about what can be obtained, which is a question we answer per request.
What is Ross Hill 0302-1500-00?
Ross Hill 0302-1500-00 identifies GE TEC36030WL, a 30 A magnetic-only motor circuit protector; keep continuous current separate from magnetic pickup settings.
What should be verified before ordering 0302-1500-00?
Verify the complete installed part number, manufacturer reference, electrical ratings, physical interface, circuit duty, and equipment configuration.

Request a quote

Request a quote by emailing sales@edmundsonindustrial.com or by calling (832) 975-8827

Identification checkpoint

For RHCC 0302-1500-00, confirm manufacturer reference: TEC36030WL; ge frame and family: E150 frame, TEC series Mag-Break; poles and rating: 3 pole, 30 A, 600 V. Use the installed label and complete suffix before treating another item as equivalent.

Want a quick quote for 0302-1500-00?

Fill out your contact info here, and we'll get a quote sent to you ASAP!