Ross Hill 0302-1500-00 Motor Circuit Protector, GE TEC36030WL
Ross Hill 0302-1500-00 identifies GE TEC36030WL, a 30 A magnetic-only motor circuit protector; keep continuous current separate from magnetic pickup settings.
Use the complete installed identifiers and equipment ratings as the ordering reference. Condition is stated with the offer.
Independent supplier. Edmundson Industrial is not appointed, endorsed, or sponsored by any manufacturer named on this page. Ross Hill, NOV, GE, Bussmann, Ohmite, Hoyt and other manufacturer names and part numbers appear here for identification only. Their use does not imply authorization, endorsement, or any current manufacturer relationship. Condition is stated with the offer.
| RHCC part number | 0302-1500-00 |
|---|---|
| Part description | CB-MAG/TRIP, 30A |
| Manufacturer reference | TEC36030WL |
| GE frame and family | E150 frame, TEC series Mag-Break |
| Poles and rating | 3 pole, 30 A, 600 V |
| Trip | Magnetic only. No thermal overload element. |
| Published trip settings | Low 90, high 390 |
| Published interrupting rating | 10 kA at 480 V, feed-thru, UL listed |
| Manufacturer status reported | Discontinued, per seller listings |
A TEC is not a THED
Fitting a TEC where a THED belongs removes the overload element from that circuit. Fitting a THED where a TEC belongs adds a thermal element to a circuit already protected by a starter overload, which is likely to nuisance trip on motor starting current. Neither is a substitution we publish.
Magnetic only is deliberate, not a cheaper option
A motor draws several times its running current for the first moments of a start. A thermal element sized to protect the motor in normal running will see that inrush and may trip on it. So on a motor circuit the protection is often split: the breaker handles short circuit with a magnetic trip only, and the starter overload relay handles sustained overload with heaters chosen for the motor.
Review the complete requirement
Send the complete part number, label photos, equipment details, and any proposed replacement already included in your requirement. EI reviews the identification and configuration with your quote request; a similar number or rating does not establish fit.
What to send with your request
Tell us what it works with, because on a motor circuit the breaker is half of a scheme.
- The ampere rating and any trip setting marked on the existing device
- The starter and overload relay the breaker works with, if you know them
- A photograph of the breaker label showing the catalogue number and any suffix
- Whether you are replacing after a fault or as part of a planned rebuild
- Quantity required, the condition you can accept, and your need-by date
Send the number and photograph with your parts requirement for EI review and a quote.
Related
Questions we get on this number
What are the trip settings?
Is it still made?
What is Ross Hill 0302-1500-00?
What should be verified before ordering 0302-1500-00?
Request a quote
Identification checkpoint
For RHCC 0302-1500-00, confirm manufacturer reference: TEC36030WL; ge frame and family: E150 frame, TEC series Mag-Break; poles and rating: 3 pole, 30 A, 600 V. Use the installed label and complete suffix before treating another item as equivalent.
Want a quick quote for 0302-1500-00?
Fill out your contact info here, and we'll get a quote sent to you ASAP!