When NOV acquired Ross Hill Controls and the Hill Hayes SCR line, most numbering carried straight over, so in most cases the Ross Hill number and the NOV number are the same. The DC control modules are the main place that changed. Here's how the common numbers line up.

Reference only: verify against the nameplate. Independent sourcing, not an authorized distributor. Ross Hill and NOV are trademarks of their respective owners, used for reference only.

What a cross-reference can and cannot tell you

Read this before you use the table. A cross-reference is an identification aid. It is not a statement that two parts are interchangeable, and on this equipment the difference matters.

  • Same number is not the same thing as same part. NOV carried most Ross Hill numbering forward unchanged, so an identical number across both brands is normal and expected. It still needs verifying against the label.
  • The dash suffix usually carries the real information. Across these families a suffix can mean a frequency, an engine calibration, a motor field configuration, or a coil voltage. Two modules that share a base number and differ in the suffix are commonly not substitutes for one another.
  • Mechanical fit proves nothing. Most of these boards will drop into the rack whether or not they are correct for the set. The failure shows up afterwards, in behaviour rather than in fitment.
  • Some cross-reference entries require nameplate confirmation. Those entries are identification leads, not interchange statements.
  • The physical nameplate outranks every secondary reference. If paperwork and hardware disagree, send the complete installed label.
The practical version: send us the number exactly as it reads on the unit, plus a photo if you can take one, and tell us the rig and drive it came out of. That is faster and cheaper than ordering against a secondary reference and discovering the mismatch on the rig floor.

Starting from a symptom rather than a number: no firing pulses, a misfire, one leg dead? The SCR Drive Fault Finder maps what you are seeing to the suspect module first.

Ross Hill to NOV cross-reference

Where the numbering lines up, where it does not, and where we have a detail page with the identification cautions for that specific item.

Ross Hill P/NNOV / equivalentPartNotes
0000-8500-00(same)AutoSync AC II moduleGenerator synchronising. Rev C and Rev E both in service.
0000-8500-18(same)AutoSync AC II, calibrated variantDash suffix is an engine calibration, not a revision. Not a substitute for the -00.
0521-2500(same)AC control module (RHCC)Base family number. SCR gate firing, drive assignment and protection.
0521-2500-14(same)AC control moduleRecorded as 50 Hz. Also seen as 521250000. Verify frequency against your set.
0521-2500-32(same)AC control moduleVariant within the AC family; suffix not yet characterised.
0522-2400-23(same)DC control module, regulationSets SCR phase angle from the driller's handwheel setpoint.
0522-2400-216415-2400-21DC control module, standardThe one confirmed case where NOV assigned its own number.
0522-2400-27(same)DC control module, series typeSeries field type, with 1K ohm resistor. Not a substitute for the shunt type.
0522-2400-00(same)DC control module, shunt typeAlso recorded as 0522-2500-00: a known numbering discrepancy on this item.
0521-2400-21(same)DC control moduleExact-match identifier; no interchange with 0522-2400-21 is assigned. Confirm the physical board label.
0401-0021-006702ED584DC contactor, 1800 A 74 VDCAn Eaton / Cutler-Hammer part, not a Ross Hill-built one. Coil voltage varies by suffix.
0100-0389-02(same)DC contactor, Ross Hill 1800/CSame 1800 A / 74 VDC headline rating as the Eaton 6702ED584 and a different part. Do not treat them as interchangeable.
0002-1076-62(same)Model 1400 blower2 HP 600 V 3-phase. SCR bay and module cooling.
0001-6307-70(same)Model 1400 SCR bridgeThyristor bridge assembly.
0100-0150-03(same)Model 1500 phase cellExplicitly not interchangeable with Model 1400 cells.
0100-1000-04(same)DWDB grid resistor assemblyDrawworks dynamic brake grid. A different item from the resistor bank below.
No RHCC number listed10509209-001Dynamic brake resistor bankAn NOV number. A different item from grid resistor 0100-1000-04.
0509-2500(same)Driller's console PCB (PC1)
0509-1300(same)Field supply PCB
0509-2600(same)Sprocket slip PCBSingle-phase. Protection function on hoisting equipment.
0509-7497(same)Power limit controller PCB
0509-7901(same)Generator exciter PCB

Reference only. Verify every number against the nameplate before ordering. Rows marked in red require physical-label confirmation and do not state interchangeability.

Numbers that are easy to confuse

These look relatedButWhat to do
0000-8500-00 and 0000-8500-18the suffix is an engine calibration, not a revisionMatch the suffix to the engine, flywheel tooth count and pickup frequency
0522-2400-27 and 0522-2400-00one is the series field type, the other the shunt typeEstablish how the motor field is wound before ordering either
0521-2400-21 and 0522-2400-21no interchange is assigned; the 0521 form requires nameplate confirmationUse the complete identifier printed on the physical board
6702ED584 and 6702ED584-2the suffix changes the coil voltage (74 VDC vs 115 VDC)Read the full number and confirm the coil voltage your bay supplies
6702ED584 and 0100-0389-02same 1800 A / 74 VDC rating, different manufacturersCheck the manufacturer name on the nameplate, not just the rating
0100-1000-04 and 10509209-001both are braking resistors and they are different assembliesConfirm which one your drawworks brake actually uses
Model 1400 and Model 1500 partsphase cells are explicitly not interchangeable between platformsEstablish the SCR platform first, then order against it

Condition & sourcing

We supply Ross Hill and NOV drilling parts as new, new-surplus, used-tested, and reconditioned, with condition disclosed before sale and photos on request. We are an independent surplus and sourcing company, not an authorized distributor.

What replaces an obsolete Ross Hill SCR drive module?

Most legacy Ross Hill / NOV modules have a direct like-for-like replacement (new-surplus, used-tested, or reconditioned), and every one of them also has a modern retrofit path when a like-for-like swap is no longer viable. Use the table to map the number printed on your board to its direct replacement and its retrofit alternative. Verify Model 1400 vs Model 1500 generation before ordering: phase cells and several PCBs are not interchangeable across generations.

Cross-reference of obsolete Ross Hill / NOV SCR drive components to direct replacement modules and modern retrofit alternatives, as supplied by Edmundson Industrial (Houston, TX). Pricing by RFQ only.
Legacy OEM PartFunctionDirect Replacement ModuleModern Retrofit PathFit NotesAvailability
0521-2500 AC control module (RHCC)SCR gate firing, drive assignment (mud pump / drawworks / rotary table), and system protection0521-2500-32: verify dash suffix and 50/60 Hz against your setPLC-based AC control retrofit within the existing SCR house footprintAlso seen collapsed as 521250000. Symptom pointer: missing or erratic gate firing pulses, drive assignment dropout.RFQ: timing confirmed with the request
0522-2400-00 DC control module, shunt typeDC motor field regulation, shunt-wound drilling motorsSame number, sourced: also recorded as 0522-2500-00Solid-state DC field controller retrofitNot interchangeable with 0522-2400-27 (series type). Confirm field configuration from the motor, not the drawing.RFQ: timing confirmed with the request
0001-6307-70 Model 1400 SCR bridgeMain AC-to-DC power conversion, one baySame number, sourcedBay rebuild with current-production SCR devices and matched firing boardsSymptom pointer: repeated semiconductor fuse loss, one leg dead, unstable DC output under load. Model 1400 bridge: do not fit to a 1500 bay.RFQ: timing confirmed with the request
0100-0150-03 Model 1500 phase cellSCR power conversion, Model 1500 generationSame number, sourcedBay rebuild with current-production SCR devices and matched firing boardsExplicitly not interchangeable with Model 1400 cells. Verify the generation before ordering.RFQ: timing confirmed with the request
0000-8500-00 AutoSync AC II moduleGenerator synchronisingSame number, sourced: Rev C and Rev E both in serviceAddressed as part of a control section refreshThe -18 suffix is an engine calibration, not a revision: the wrong calibration will not sync even on a healthy module.RFQ: timing confirmed with the request
6702ED584 DC contactor, 1800 A 74 VDCDC power contactor in the SCR baySame number, sourced: Ross Hill reference 0401-0021-00Contactors inspected during rebuild; contacts and coils addressedCoil voltage varies by suffix. Same headline rating as Ross Hill 0100-0389-02 and a different part: not interchangeable.RFQ: timing confirmed with the request
0002-1076-62 Model 1400 blowerSCR bay and module cooling (2 HP, 600 V 3-phase)Same number, sourcedCooling restored during rebuild: blowers, filters, airflow pathsOverheating bays and thermal trips are a cooling symptom before they are an electronics symptom.RFQ: timing confirmed with the request

Number not in the table? Send whatever is printed on the board, including numbers that look wrong, to Request a Quote. Documented numbering discrepancies (2400 vs 2500 middle groups, collapsed no-dash formats) are normal on this equipment and we cross-reference them daily.

FAQ

Did NOV change the Ross Hill part numbers?
Mostly no. NOV carried most Ross Hill / Hill Hayes numbering forward, so the same number usually applies. The DC control modules are the main exception, where NOV used distinct 6415- numbers.
Is your cross-reference guaranteed?
It is a reference to help you identify the right part. Always verify the exact dash number and revision against the module or nameplate label before ordering; we confirm at quote.
Which Ross Hill or NOV identifier can I send?
Yes. Send whichever number you have and we will identify the part and source it as new old stock, surplus, used-tested, or reconditioned.
Are you an authorized distributor?
No. Edmundson Industrial is an independent surplus and sourcing company, not an authorized distributor.

Request a Quote

Request a Quote

or send the part number to sales@edmundsonindustrial.com · (832) 975-8827 · Houston, TX. Response timing is confirmed with the request.

Related

Send the Ross Hill or NOV number and we'll identify and source it.

Condition disclosed before sale. Response timing is confirmed with the request.

Request a Quote