Drilling Rig SCR House Replacement Parts
Ross Hill and NOV SCR house parts: control modules, bridges, phase cells, console boards, contactors and fuses. Send a part number or describe the symptom.
An SCR house takes AC from the engine-generator sets and converts it to controlled DC for the drilling motors. When something in that chain fails, the rig stops. Most of this equipment is decades old, long out of production, and not stocked by mainstream distributors, which is exactly the gap Edmundson Industrial works in.
Independent sourcing, not an authorized distributor. Ross Hill, NOV, and other manufacturer names are used for reference only. We supply new-surplus, used-tested, and reconditioned equipment with condition disclosed before sale.
Start from the symptom
The Ross Hill SCR Drive Fault Finder maps the common failure signatures: gate firing pulse failure, misfire, one leg dead, phase loss, assignment dropout, autosync hunt: to the suspect module and its part number.
Most people calling about an SCR house do not have a part number yet: they have a rig that will not do something. These are the common entry points.
| What the rig is doing | Where to look |
|---|---|
| Generator will not build voltage, or hunts under load | Generator exciter PCB |
| Engines bog or black out on simultaneous heavy loads | Power limit controller |
| Drilling motor will not reach speed, or overspeeds | Field supply PCB |
| Handwheel does nothing; console indication disagrees | Driller's console PCB |
| Semiconductor fuse blows repeatedly on one drive | SCR bridgephase cell |
| Reduced or absent dynamic braking | DWDB grid resistor |
| Drive will not take assignment | AC moduleDC module |
These are starting points, not a diagnosis. Symptoms overlap across the control chain: tell us what you are seeing and we will help narrow it before you buy anything.
Control modules
The cards that regulate the drives. AC modules handle generator-side control and synchronising; DC modules set SCR phase angle and run the current and speed regulation loop for the drilling motors.
| Item | Part number | |
|---|---|---|
| Ross Hill AC Module | 0521-2500 series | View › |
| Ross Hill DC Module | 0522-2400-23 · NOV 6415-2400-21 | View › |
| AutoSync AC II Module | 0000-8500-00 · 0000-8500-18 | View › |
| DC Module, standard | 0522-2400-21 · NOV 6415-2400-21 | View › |
| DC Module, series type | 0522-2400-27 | View › |
| DC Module, shunt type | 0522-2400-00 | View › |
| Power Modules | SCR power module assemblies | View › |
Power conversion
Where generated AC becomes controlled DC. Bridges, phase cells, pucks and the semiconductor fuses that protect them.
| Item | Part number | |
|---|---|---|
| Model 1400 SCR Bridge | 0001-6307-70 | View › |
| Model 1500 Phase Cell | 0100-0150-03 | View › |
| DC Contactor (Eaton / Cutler-Hammer) | 6702ED584 · 0401-0021-00 | View › |
| DC Contactor (Ross Hill 1800/C) | 0100-0389-02 | View › |
| Model 1400 Blower | 0002-1076-62 | View › |
| SCR Bay Components | pucks, fuses, snubbers | View › |
Generator & field control
Excitation, power limiting and field supply: the loop that keeps the plant stable under drilling load.
| Item | Part number | |
|---|---|---|
| AutoSync AC II Module | 0000-8500-00 | View › |
| Generator Exciter PCB | 0509-7901 | View › |
| Power Limit Controller PCB | 0509-7497 | View › |
| Field Supply PCB | 0509-1300 | View › |
Driller's console & protection
The operator interface and the protective functions behind it.
| Item | Part number | |
|---|---|---|
| Driller's Console PCB, PC1 | 0509-2500 | View › |
| Sprocket Slip PCB | 0509-2600 | View › |
| DWDB Grid Resistor Assembly | 0100-1000-04 | View › |
Looking for a complete house?
This page covers replacement parts. If you are sourcing or evaluating a complete system, start at SCR Houses: including the used-house buying guide and SCR vs VFD, Model 1400, Model 1500, and rebuild & retrofit.
Cross-referencing Ross Hill to NOV
NOV retained most Ross Hill numbering after acquiring the line. The DC control modules are the main exception. Our Ross Hill / NOV cross-reference lists what we have confirmed, flags what we have not, and calls out the numbers that look interchangeable but are not.
FAQ
What parts of an SCR house do you supply?
Do you handle both Ross Hill and NOV numbers?
Are these parts new?
I do not know the part number: can you still help?
How fast can you respond?
Availability & Quote
Condition disclosed before sale. Photos on request. Response timing is confirmed with the request.
Rig down? Send the number or the symptom.
Condition disclosed before sale. Response timing is confirmed with the request.