Ross Hill 0301-0009-00 identifies a 0.6 A, 500 V time-delay midget fuse; confirm the exact ATQ or FNQ family marking and installed holder before ordering.

Ross Hill 0301-0009-00 identifies a 0.6 A, 500 V time-delay midget fuse; confirm the exact ATQ or FNQ family marking and installed holder before ordering. Use the complete installed identifiers and equipment ratings as the ordering reference. Availability, condition, price, and lead time are confirmed for each request.

Independent supplier. Edmundson Industrial is not appointed, endorsed, or sponsored by any manufacturer named on this page. Ross Hill, NOV, GE, Bussmann, Ohmite, Hoyt and other manufacturer names and part numbers appear here for identification only. Their use does not imply authorization, endorsement, or any current manufacturer relationship. Availability, condition, price, and lead time are confirmed for each request.

Identification details for Ross Hill 0301-0009-00
RHCC part number0301-0009-00
Part descriptionFUSE-FNQ 6/10AMP
Manufacturer referenceATQ.6
What 6/10 meansSix tenths of one amp, 0.6 A
Rating reported elsewhere0.6 A, 500 V, 10 kA interrupting
Type reportedMidget time-delay
Published dimensions for the equivalent Bussmann reference0.410 by 1.500 inches

The trap, in both numbering systems at once

Ross Hill 0301-0009-00 part-number comparison
RHCC numberPart descriptionManufacturer referenceActual rating
0301-0009-00FUSE-FNQ 6/10AMPATQ.60.6 A
0301-0012-00FUSE-FNQ 6 AMPATQ66 A

A control circuit protected by a 6 A fuse where 0.6 A was intended is protected by very little. The failure is not immediate and not obvious, which is what makes it worth a page.

The whole fuse block on this equipment

Five fuses in the 0301 block share a family and a voltage and differ only in rating.

Ross Hill 0301-0009-00 part-number comparison
RHCC numberPart descriptionReferenceGroup
0301-0009-00FUSE-FNQ 6/10AMPATQ.6GEN
0301-0010-00FUSE-FNQ 2 AMPATQ2GEN
0301-0011-00FUSE-FNQ 3.5 AMPATQ3.5SCR
0301-0012-00FUSE-FNQ 6 AMPATQ6GEN
0301-0013-00FUSE-FNQ 10 AMPATQ10SCR

Two things are worth noticing. The 3.5 A row uses a decimal point in the reference the same way the 0.6 A row does, so the punctuation is doing real work throughout. And the block spans two system groups, so a store that files by group will have these five in two places.

Also searched as

0301-0009-00 · 0301000900 · ATQ.6 · FNQ-6/10 · FNQ 6/10 · 0.6 amp 500 V midget time delay fuse

What is worth knowing is that the FNQ family has a rejection-style variant, FNQ-R, and rejection-style fuses and holders exist specifically so that the wrong fuse will not go in. We did not establish which holders this equipment uses, so we are not telling you whether an FNQ and an FNQ-R will interchange in your panel. Send us the holder and we will treat it as a real question rather than a guess.

What to send with your request

The printing on the fuse body settles this one in about ten seconds.

  • The complete printing on the fuse body, read character by character including any slash or decimal point
  • A photograph of the fuse and, if you can, of the holder it came out of
  • Whether the circuit is control, indication, or something else, if you know
  • Quantity required, remembering that these are usually held in tens
  • The condition you can accept and your need-by date

We do not need a purchase order to answer an identification question. Send the number and the photograph and we will tell you what we can establish.

Related

Questions we get on this number

What are the other fuses in this block?
0301-0010-00 at 2 A, 0301-0011-00 at 3.5 A, 0301-0012-00 at 6 A and 0301-0013-00 at 10 A, alongside this one at 0.6 A. The block spans the generator and SCR groups, so a store that files by system group will have them in two places.
What is Ross Hill 0301-0009-00?
Ross Hill 0301-0009-00 identifies a 0.6 A, 500 V time-delay midget fuse; confirm the exact ATQ or FNQ family marking and installed holder before ordering.
What should be verified before ordering 0301-0009-00?
Verify the complete installed part number, manufacturer reference, electrical ratings, physical interface, circuit duty, and equipment configuration.
What should I send for a 0301-0009-00 quote?
Send clear label and equipment photographs, all identifiers, relevant electrical and mechanical ratings, quantity, acceptable condition, and need-by date.

Availability and quote

Request a quote by emailing sales@edmundsonindustrial.com or by calling (832) 975-8827

Identification checkpoint

For RHCC 0301-0009-00, confirm manufacturer reference: ATQ.6; rating reported elsewhere: 0.6 A, 500 V, 10 kA interrupting; what 6/10 means: Six tenths of one amp, 0.6 A. Use the installed label and complete suffix before treating another item as equivalent.