Ross Hill 0509-1300: Field Supply PCB

The field supply card in a Ross Hill / NOV SCR drive. It provides and regulates field current to the DC drilling motors.

Independent supplier. RHCC 0509-1300 is identified from the installed number. Manufacturer and trademark names are used for reference only, and condition is disclosed before sale.

Part number0509-1300
SystemRoss Hill / Hill Hayes / NOV SCR drilling
FunctionDC drive control
ConditionNew-surplus, used-tested, reconditioned
Also searched as0509-1300 · 05091300 · 1300 · Ross Hill · NOV · Hill Hayes

What it does

A DC drilling motor develops torque from armature current acting against motor field. The field supply card provides that field. Because field weakening is how these drives reach higher speed, a fault here shows up as a speed and torque problem rather than an obvious electrical failure: a motor that will not reach speed, or one that runs away above base speed.

Symptoms that point here

What you are seeingWhat it usually indicates
Motor will not reach rated speedField not weakening correctly at the top of the range
Motor overspeeds or runs awayLoss of field: treat as urgent
Low torque at low speedField current below rating
Drive faults on overcurrent under normal loadArmature compensating for weak field
No field or weak field on a DC drilling motor after the DC module checks outThe field supply PCB is the next suspect in the field path: confirm shunt vs series from the motor, not the drawing

Confirm the installed unit

For 0509-1300, send the complete dash number and a clear nameplate or board-label photo. The quoted unit is matched to the supplied identifier before condition and lead time are confirmed.

Condition and sourcing

RHCC 0509-1300 is quoted only after current availability, condition, and lead time are confirmed. Any offered unit is identified as new-surplus, used-tested, or reconditioned before sale.

If the observed failure does not line up with RHCC 0509-1300, use the SCR Drive Fault Finder to narrow the subsystem before requesting a part.

FAQ

What does the field supply PCB do?
Part 0509-1300 provides and regulates field current to the DC drilling motor in a Ross Hill / NOV drive.
Why does a field fault cause overspeed?
A DC motor speeds up as field is weakened. Lose field entirely with armature voltage applied and the motor can run away. It is a condition to take seriously.
Do you have it?
We source it as new-surplus, used-tested, and reconditioned. Send the number and we will tell you what we can find.