Drilling, workover, and production. This is where the company came up, and where the part-level knowledge on this site runs deepest.
This is where the company came from, and it is where the deepest part-level knowledge on this site sits. A rig standing still burns day rate whether the problem is a twenty-dollar board or a whole SCR bay, and everyone on that spread knows what the hour costs. That is the standard we hold to on every other call we take.
Most rig electrical calls are not exotic. They are a known board in a known bay on a control system that went out of production while the rig kept working. The SCR house is where the majority of them land.
| What went down | What we supply |
|---|---|
| SCR bay drops a bridge. Drawworks or mud pump loses torque, or trips on overcurrent. | Model 1400 SCR bridges, Model 1500 phase cells, and power modules |
| Generator will not build voltage or pick up load. Exciter suspected. | Generator exciter PCBs |
| Engines will not parallel. Sync fault on the SCR house control. | AutoSync AC II modules (Rev C and Rev E are not interchangeable — send the revision off the plate) |
| Driller's console dead, or a single function lost with the rest live. | Driller's console PCBs |
| Drawworks will not hold on dynamic braking. Grid or resistor bank suspected. | DWDB grid resistors and NOV dynamic brake resistor banks |
| AC section faults, or an assignment will not transfer between motors. | AC control modules and Ross Hill AC modules |
| Rig blacks out under load, or power limit is cutting in early. | Power limit controller PCBs |
| Rotary or drawworks slip alarm with no mechanical cause found. | Sprocket slip PCBs |
| DC motor field weak or unstable. Field supply suspected. | Field supply PCBs |
| Whole SCR house is aging out and parts are getting harder to find every year. | Rebuild and retrofit options, or the SCR versus VFD comparison if conversion is on the table |
Every part above has its own page with what we know about the unit and what we still need you to confirm off the physical nameplate. Start at drilling rig electrical or the Ross Hill / NOV cross-reference.
Away from the rig floor the equipment is ordinary industrial electrical, and the failures look like any other plant. What is different is the location. A compressor station two hours from the nearest supply house has the same problem as a rig — the part is not down the road, and nobody is driving it out tonight.
| What went down | What we supply |
|---|---|
| ESP or transfer pump drive failed and the model is discontinued. | Drives and VFDs across current and obsolete lineups, plus an honest repair-or-replace read |
| MCC bucket burned up at a compressor station or production facility. | MCC buckets and MCC parts for lineups no longer in production |
| Breaker frame in the facility switchgear is discontinued and cannot be re-racked. | Obsolete breaker cross-reference and circuit breakers |
| Starter or contactor coil failure on a pump, fan, or compressor. | Contactors and motor control, motor starters, and soft starters |
| Legacy DC drive still running a workover unit or a lease pump. | SCR and DC drive systems |
| Replacement does not fit the old footprint, or the enclosure is gone. | Fabricated enclosures, panels, brackets, and adapter plates |
On a drilling rig, an electrical fault does not generate a maintenance ticket. It stops the entire spread, and the day rate runs regardless. On the production side it is quieter and slower but not cheaper — a shut-in well or a compressor off line is deferred production that does not come back.
We are not going to put a dollar figure on your hour. You already know it, and it is not the same as the rig down the road. What we will do is answer inside the hour, tell you plainly when we cannot find something, and not let a quote sit overnight waiting on an internal approval.
Most urgent calls do not start with a clean number. Send a photo of the nameplate and the unit, tell us what the equipment is doing, and we will work backwards. For drilling systems the Ross Hill / NOV cross-reference maps the numbers that cause the most trouble. For everything else the general cross-reference covers obsolete-to-current paths across the major manufacturers.
Same-day applies to stocked items. Sourced items move as fast as the supply chain allows, and we give you a real lead time rather than an optimistic one. We do not publish stock levels, because they change — ask, and you get the actual answer for that day.
We do not publish Zeefax or other manufacturers' part numbers as equivalents to Ross Hill numbers. Those companies build their own products; a number from one is not a cross-reference for the other, and we are not going to imply otherwise to catch search traffic. If you have a cross-reference off a datasheet or a job you have run, send it and we will work from it.
We are an independent supply and sourcing company, not an authorized distributor. Condition is disclosed before sale on every item we supply — new, new-surplus, used-tested, or reconditioned.